Module 30 of 49 · Part 5 – Spas, covers and special pools · About 8 minutes · Sources checked 17 November 2026
A spa cover is a barrier – only when it’s closed and locked.
Check a spa cover against F9.3.5 and F9/AS2: the 760 mm wall, strength, slope, lockable straps, the 100 mm sphere test and the warning sign.
Read the module in the flip book below. The cover image is AI-generated and illustrative only. A short quiz is at the end of the module, with answers included.
On-screen flip book · 7 pages
Page 1 of 7
Key learning points
- F9.3.5: a cover used as a barrier to a small heated pool must restrict entry of children when closed, withstand a reasonably foreseeable load, be readily returned to the closed position, and carry signage about its child-safety features.
- F9/AS2 scope: water surface ≤ 5 m², walls 760 mm above the adjacent floor or ground; an adult must be able to readily close the cover.
- Walls vertical or sloping outward ≤ 15°; no climbable objects within 760 mm of the top edge; no wall projections or indentations over 10 mm.
- Cover supports a 200 N (20 kg) point load over 120 mm diameter at the centre; top slopes to shed water.
- Straps with lockable snap fasteners ≥ 33 mm wide (or metal padlocks); with 100 N applied anywhere, no gap passes a 100 mm sphere.
- Warning sign on two opposite sides, black letters ≥ 5 mm.
Key terms
| Term | Meaning | Where |
|---|---|---|
| Lockable snap fastener | Strap fastener that locks; ≥ 33 mm wide on its main body. | F9/AS2 2.4.1 |
| 100 N test | Force (about 10 kg) applied in any direction anywhere on the cover; no opening a 100 mm sphere could pass. | F9/AS2 2.4.3 |
| 200 N point load | Vertical load over 120 mm diameter at the centre the cover must support. | F9/AS2 2.2.1 |
| R760 | The 760 mm arc used in Figure 1 for spas in place of R1200. | F9/AS2 2.1.2, Fig 1 |
Official references
| Document | Version | Used for |
|---|---|---|
| Building Code clause F9 (Building Regulations 1992 Sch 1) | Version as at 15 January 2026 | F9.3.5 |
| MBIE Acceptable Solutions F9/AS1 & F9/AS2 | First Edition, effective 27 April 2017; captured 17 Nov 2026 | AS2 1.0, 2.1–2.5, Figure 1 |
Please read first. This guide is general information for learning only. It is not formal engineering, legal or compliance approval. Always check requirements with your Building Consent Authority or a qualified professional. Contact BlueHaven at support@bluehaven.nz.