A spa cover is a barrier – only when it’s closed and locked.

Check a spa cover against F9.3.5 and F9/AS2: the 760 mm wall, strength, slope, lockable straps, the 100 mm sphere test and the warning sign.

Read the module in the flip book below. The cover image is AI-generated and illustrative only. A short quiz is at the end of the module, with answers included.

On-screen flip book · 7 pages

Page 1 of 7

Key learning points

  • F9.3.5: a cover used as a barrier to a small heated pool must restrict entry of children when closed, withstand a reasonably foreseeable load, be readily returned to the closed position, and carry signage about its child-safety features.
  • F9/AS2 scope: water surface ≤ 5 m², walls 760 mm above the adjacent floor or ground; an adult must be able to readily close the cover.
  • Walls vertical or sloping outward ≤ 15°; no climbable objects within 760 mm of the top edge; no wall projections or indentations over 10 mm.
  • Cover supports a 200 N (20 kg) point load over 120 mm diameter at the centre; top slopes to shed water.
  • Straps with lockable snap fasteners ≥ 33 mm wide (or metal padlocks); with 100 N applied anywhere, no gap passes a 100 mm sphere.
  • Warning sign on two opposite sides, black letters ≥ 5 mm.

Key terms

TermMeaningWhere
Lockable snap fastenerStrap fastener that locks; ≥ 33 mm wide on its main body.F9/AS2 2.4.1
100 N testForce (about 10 kg) applied in any direction anywhere on the cover; no opening a 100 mm sphere could pass.F9/AS2 2.4.3
200 N point loadVertical load over 120 mm diameter at the centre the cover must support.F9/AS2 2.2.1
R760The 760 mm arc used in Figure 1 for spas in place of R1200.F9/AS2 2.1.2, Fig 1

Official references

DocumentVersionUsed for
Building Code clause F9 (Building Regulations 1992 Sch 1)Version as at 15 January 2026F9.3.5
MBIE Acceptable Solutions F9/AS1 & F9/AS2First Edition, effective 27 April 2017; captured 17 Nov 2026AS2 1.0, 2.1–2.5, Figure 1