Module 20 of 49 · Part 3 – Barrier essentials: F9/AS1 · About 9 minutes · Sources checked 17 November 2026
Your neighbour’s side of the fence is out of your control.
Apply F9/AS1’s boundary-barrier option – 1800 mm from the pool side, no 100 mm openings, 1000 mm from the water and a 900 mm pool-side zone – and fit it with consent and planning rules.
Read the module in the flip book below. The cover image is AI-generated and illustrative only. A short quiz is at the end of the module, with answers included.
On-screen flip book · 7 pages
Page 1 of 7
Key learning points
- Four conditions for a pool barrier on a property boundary (F9/AS1 2.2.1): (a) at least 1800 mm high, measured from the ground on the pool side; (b) no openings a 100 mm sphere could pass through; (c) at least 1000 mm horizontally from the water’s edge; (d) a 900 mm climb-resistant zone on the pool side, starting not more than 150 mm from the top.
- Why stricter? The pool owner can’t control what is placed on the neighbour’s side.
- Consent: the usual fence exemption (Sch 1 cl 21) does not cover a fence to restrict access to a residential pool.
- Planning: in the Single House zone, side and rear fences are limited to 2 m measured from the ground at the boundary (AUP H3.6.12).
Key terms
| Term | Meaning | Where |
|---|---|---|
| Boundary barrier | Pool barrier located on a property boundary. | F9/AS1 2.2 |
| Water’s edge | Not defined in F9/AS1; the 1000 mm is measured horizontally from it. | F9/AS1 2.2.1(c) |
| Pool-side zone | 900 mm climb-resistant zone near the top, on the pool side. | F9/AS1 2.2.1(d) |
| Yard | Area along a boundary where AUP standards apply. | AUP J1; H3.6 |
Official references
| Document | Version | Used for |
|---|---|---|
| MBIE Acceptable Solutions F9/AS1 & F9/AS2 | First Edition, effective 27 April 2017; captured 17 Nov 2026 | AS1 2.1.2, 2.2 |
| Building Act 2004 Sch 1 cl 21 | Version as at 8 October 2026; saved 17 Nov 2026 | Fence exemption and pool exclusion |
| Auckland Council – “Other structures used as part of the pool barrier” | Web page, captured 17 Nov 2026 | Boundary fencing guidance |
| Auckland Unitary Plan H3 Residential – Single House Zone | PDF footer “July 2026”; downloaded 17 Nov 2026 | H3.6.12 fences |
Please read first. This guide is general information for learning only. It is not formal engineering, legal or compliance approval. Always check requirements with your Building Consent Authority or a qualified professional. Contact BlueHaven at support@bluehaven.nz.