Module 35 of 49 · Part 5 – Spas, covers and special pools · About 8 minutes · Sources checked 17 November 2026
One barrier, two jobs – design to the stricter rule every time.
Handle a barrier that must stop a fall (F4) and keep out young children (F9) – deck-edge pool fences, raised pool walls and infinity edges.
Read the module in the flip book below. The cover image is AI-generated and illustrative only. A short quiz is at the end of the module, with answers included.
On-screen flip book · 6 pages
Page 1 of 6
Key learning points
- F4.3.1: a barrier is required where people could fall 1 m or more.
- F4/AS1 Table 1: in detached dwellings, barriers on balconies and decks are at least 1000 mm. F9/AS1 2.1.2: a pool barrier is at least 1200 mm.
- Both use the 100 mm sphere for openings; F4/AS1 warns horizontal rails are easily climbed; F9/AS1 adds the non-climbable zone and projection rules.
- A dual-purpose barrier must meet every requirement of both – in practice, the stricter number each time.
- Infinity (vanishing) edge: the outside of the edge wall faces the drop. F9/AS1 2.3.1 lets a pool wall be the barrier only if ≥ 1200 mm and meeting 2.1.6–2.1.7; its Comment flags F4 where the wall top is ≥ 1000 mm above ground.
Key terms
| Term | Meaning | Where |
|---|---|---|
| Dual-purpose barrier | A barrier that must meet both F4 (falls) and F9 (pool access). | F4, F9 |
| Balustrade height (deck) | ≥ 1000 mm for balconies and decks in detached dwellings. | F4/AS1 Table 1 |
| Pool barrier height | ≥ 1200 mm. | F9/AS1 2.1.2 |
| Infinity edge | Pool wall water spills over into a catch trough. | – |
Official references
| Document | Version | Used for |
|---|---|---|
| Building Code clause F4 (Building Regulations 1992 Sch 1) | Version as at 15 January 2026 | F4.3.1 |
| MBIE Compliance Document F4 Safety from Falling (F4/AS1) | 3rd edition, Amendment 2 effective 1 January 2017; retrieved 17 Nov 2026 | 1.1–1.2.1, Table 1 |
| MBIE Acceptable Solutions F9/AS1 & F9/AS2 | First Edition, effective 27 April 2017 | AS1 2.1.2–2.1.3, 2.3 |
Please read first. This guide is general information for learning only. It is not formal engineering, legal or compliance approval. Always check requirements with your Building Consent Authority or a qualified professional. Contact BlueHaven at support@bluehaven.nz.
Previous: Module 34: Pools on decks, roofs and elevated sites Back to guide Next: Module 36 – Coming soon