Your neighbour’s side of the fence is out of your control.

Apply F9/AS1’s boundary-barrier option – 1800 mm from the pool side, no 100 mm openings, 1000 mm from the water and a 900 mm pool-side zone – and fit it with consent and planning rules.

Read the module in the flip book below. The cover image is AI-generated and illustrative only. A short quiz is at the end of the module, with answers included.

On-screen flip book · 7 pages

Page 1 of 7

Key learning points

  • Four conditions for a pool barrier on a property boundary (F9/AS1 2.2.1): (a) at least 1800 mm high, measured from the ground on the pool side; (b) no openings a 100 mm sphere could pass through; (c) at least 1000 mm horizontally from the water’s edge; (d) a 900 mm climb-resistant zone on the pool side, starting not more than 150 mm from the top.
  • Why stricter? The pool owner can’t control what is placed on the neighbour’s side.
  • Consent: the usual fence exemption (Sch 1 cl 21) does not cover a fence to restrict access to a residential pool.
  • Planning: in the Single House zone, side and rear fences are limited to 2 m measured from the ground at the boundary (AUP H3.6.12).

Key terms

TermMeaningWhere
Boundary barrierPool barrier located on a property boundary.F9/AS1 2.2
Water’s edgeNot defined in F9/AS1; the 1000 mm is measured horizontally from it.F9/AS1 2.2.1(c)
Pool-side zone900 mm climb-resistant zone near the top, on the pool side.F9/AS1 2.2.1(d)
YardArea along a boundary where AUP standards apply.AUP J1; H3.6

Official references

DocumentVersionUsed for
MBIE Acceptable Solutions F9/AS1 & F9/AS2First Edition, effective 27 April 2017; captured 17 Nov 2026AS1 2.1.2, 2.2
Building Act 2004 Sch 1 cl 21Version as at 8 October 2026; saved 17 Nov 2026Fence exemption and pool exclusion
Auckland Council – “Other structures used as part of the pool barrier”Web page, captured 17 Nov 2026Boundary fencing guidance
Auckland Unitary Plan H3 Residential – Single House ZonePDF footer “July 2026”; downloaded 17 Nov 2026H3.6.12 fences